Difference between revisions of "EthernetIPforCLXCom"
(→EthernetIPforCLXCom) |
(→EthernetIPforCLXCom) |
||
Line 11: | Line 11: | ||
''CIPConnectionSize'' - The maximum number of bytes in a single packet. The larger the number, the more efficient the communications. A value of 508 works with all Allen Bradley PLCs tested. Some of the newer models will allow a higher value.<br> | ''CIPConnectionSize'' - The maximum number of bytes in a single packet. The larger the number, the more efficient the communications. A value of 508 works with all Allen Bradley PLCs tested. Some of the newer models will allow a higher value.<br> | ||
− | ''DisableMultiServiceRequest'' - A multi-service request allows more than one request per packet. This can dramatically increase the speed of retrirving values. Not all PLCs support this, such as the Micro800 series. | + | ''DisableMultiServiceRequest'' - A multi-service request allows more than one request per packet. This can dramatically increase the speed of retrirving values. Not all PLCs support this, such as the Micro800 series.<br> |
+ | |||
+ | ''DisableSubscriptions'' - Paused updating of subscriptions. This is useful in cases such as when hiding a form and there is no longer a need to refresh the values. Or when used with a Trend Chart, it can pause the charting.<br> | ||
+ | |||
+ | ''PollRateOverride'' - This set the target rate for refreshing all of the subscriptions. When there are a large number of subscriptions that have to be split amongst sever requests, this value is divided by the number of requests required to determine the delay between each packet. A value of 0 will make the driver update as fast as the PLC will respond, but be cautious because it can reach rates less than 5ms and start to use a lot of resources. | ||
+ | |||
+ | ''Port'' - The TCP/IP port. In nearly all cases this will be 44818 | ||
+ | |||
+ | ''INIFileName'' - An INI file can be created to store the properties for being set during application startup. See [[INI File Usage]] for more details | ||
+ | |||
+ | ''INIFileSection'' - Specifies the section within the INI file |
Revision as of 08:13, 3 September 2016
EthernetIPforCLXCom
This driver specifically targets the Allen Bradley line of ControlLogix and CompactLogix PLCs. It uses tag names directly to access data values in the PLC.
Properties
IPAddress - The TCP/IP address of the PLC to communicate with
CIPConnectionSize - The maximum number of bytes in a single packet. The larger the number, the more efficient the communications. A value of 508 works with all Allen Bradley PLCs tested. Some of the newer models will allow a higher value.
DisableMultiServiceRequest - A multi-service request allows more than one request per packet. This can dramatically increase the speed of retrirving values. Not all PLCs support this, such as the Micro800 series.
DisableSubscriptions - Paused updating of subscriptions. This is useful in cases such as when hiding a form and there is no longer a need to refresh the values. Or when used with a Trend Chart, it can pause the charting.
PollRateOverride - This set the target rate for refreshing all of the subscriptions. When there are a large number of subscriptions that have to be split amongst sever requests, this value is divided by the number of requests required to determine the delay between each packet. A value of 0 will make the driver update as fast as the PLC will respond, but be cautious because it can reach rates less than 5ms and start to use a lot of resources.
Port - The TCP/IP port. In nearly all cases this will be 44818
INIFileName - An INI file can be created to store the properties for being set during application startup. See INI File Usage for more details
INIFileSection - Specifies the section within the INI file