|This set the target rate for refreshing all of the subscriptions. When there are a large number of subscriptions that have to be split amongst sever requests, this value is divided by the number of requests required to determine the delay between each packet. A value of 0 will make the driver update as fast as the PLC will respond, but be cautious because it can reach rates less than 5ms and start to use a lot of resources. | |This set the target rate for refreshing all of the subscriptions. When there are a large number of subscriptions that have to be split amongst sever requests, this value is divided by the number of requests required to determine the delay between each packet. A value of 0 will make the driver update as fast as the PLC will respond, but be cautious because it can reach rates less than 5ms and start to use a lot of resources. | ||
+ | |- | ||
+ | |INIFileName | ||
+ | |An INI file can be created to store the properties for being set during application startup. See [[INI File Usage]] for more details | ||
+ | |- | ||
+ | |INIFileSection | ||
+ | |Specifies the section within the INI file to use | ||
|} | |} | ||
Revision as of 06:39, 4 September 2016
EthernetIPforCLXCom
This driver specifically targets the Allen Bradley line of ControlLogix and CompactLogix PLCs. It uses tag names directly to access data values in the PLC.
Properties | |
---|---|
IPAddress | The TCP/IP address of the PLC to communicate with |
Port | The TCP/IP port. In nearly all cases this will be 44818 |
CIPConnectionSize | The maximum number of bytes in a single packet. The larger the number, the more efficient the communications. A value of 508 works with all Allen Bradley PLCs tested. Some of the newer models will allow a higher value. |
DisableMultiServiceRequest | A multi-service request allows more than one request per packet. This can dramatically increase the speed of retrirving values. Not all PLCs support this, such as the Micro800 series. |
DisableSubscriptions | uses updating of subscriptions. This is useful in cases such as when hiding a form and there is no longer a need to refresh the values. Or when used with a Trend Chart, it can pause the charting. |
PollRateOverride | This set the target rate for refreshing all of the subscriptions. When there are a large number of subscriptions that have to be split amongst sever requests, this value is divided by the number of requests required to determine the delay between each packet. A value of 0 will make the driver update as fast as the PLC will respond, but be cautious because it can reach rates less than 5ms and start to use a lot of resources. |
INIFileName | An INI file can be created to store the properties for being set during application startup. See INI File Usage for more details |
INIFileSection | Specifies the section within the INI file to use |
Properties
IPAddress - The TCP/IP address of the PLC to communicate with
CIPConnectionSize - The maximum number of bytes in a single packet. The larger the number, the more efficient the communications. A value of 508 works with all Allen Bradley PLCs tested. Some of the newer models will allow a higher value.
DisableMultiServiceRequest - A multi-service request allows more than one request per packet. This can dramatically increase the speed of retrirving values. Not all PLCs support this, such as the Micro800 series.
DisableSubscriptions - Pauses updating of subscriptions. This is useful in cases such as when hiding a form and there is no longer a need to refresh the values. Or when used with a Trend Chart, it can pause the charting.
PollRateOverride - This set the target rate for refreshing all of the subscriptions. When there are a large number of subscriptions that have to be split amongst sever requests, this value is divided by the number of requests required to determine the delay between each packet. A value of 0 will make the driver update as fast as the PLC will respond, but be cautious because it can reach rates less than 5ms and start to use a lot of resources.
Port - The TCP/IP port. In nearly all cases this will be 44818
INIFileName - An INI file can be created to store the properties for being set during application startup. See INI File Usage for more details
INIFileSection - Specifies the section within the INI file
Methods
For the methods common to all drivers see the section on the IComComponent
GetTagList() - Returns the list of controller scope and program scope tags. This is a synschronous method and can delay for a long time when reading a program with a very large tag list.
Addressing
Controller scope tags are addressed by directly using the tag name. For example:
MyTag
Program scope tags require a prefix to indicate which program. For example:
PROGRAM:MainRoutine.MyTag
UDT elements are read by specifying the UDT variable. For example:
MyUDTTag.Element