AnalogValueDisplay
Revision as of 16:22, 8 September 2016 by Arj3090 (talk | contribs) (Arj3090 moved page Analog Value Display to AnalogValueDisplay)
Analog Value Display
This control displays an analog value and has specific functionality geared toward representing the value in different formats.
Properties | |
---|---|
ComComponent | Points to the driver instance for reading its values through |
ForeColorInLimits | The color of the text when the value is within ValueLimitLower and ValueLimitUpper |
ForeColorOverLimit | The color of the text when the value is greater than ValueLimitUpper |
ForeColorUnderLimit | The color of the text when the value is less than ValueLimitLower |
PLCAddressKeypad | If a valid PLC address is put in this property, during run-time a keypad will pop up when the control is clicked. The value entered into the keypad will be written to the address as defined in this property. |
PLCAddressValue | The register in the PLC to read for the value to display and deteremine the text color as defined in the ForeColorXXX properties |
PLCAddressValueLimitLower | Used to dynamically set ValueLimitLower from a value in the PLC |
PLCAddressValueLimitUpper | Used to dynamically set ValueLimitUpper from a value in the PLC |
ValueLimitLower | Determines at what value to switch the text color to ForeColorUnderLimit. Also works with VisibleControl property |
ValueLimitUpper | Determines at what value to switch the text color to ForeColorOverLimit. Also works with VisibleControl property |
VisibleControl | Determines when the control is shown. Defaults to Always, but can make it hide in determination with the ValueLimit properties |